• Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
  • Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
  • Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
  • Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
  • Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor

Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Structure Type: Closed Type
Installation Type: Stationary Type
Product: 15kw 20HP Air Compressor
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (23)

Basic Info.

Model NO.
AS-15HVF
Application
General Industry,Laser Cutting, Texitle and So on
MOQ
1 Set for 20HP Compressor
Warranty
1 Year for Air Compressor
Cooling Method
Air/Water Cooling Air Compressor
Capacity
1.8m3/Min for 15kw Air Compressor
Connection Way
Direct Driven/Belt Driven 20HP Air Compressor
Compressor Stage
Single-Stage/Double-Stage 20HP Compressor
Noise
65dB for 20HP Air Compressor
Speed
2960r/Min for 20HP Air Compressor
Air End
Hanbell/Baosi Airend 20HP Air Compressor
Pressure
0.4/0.7/0.8/1.0/1.6MPa 20HP Air Compressor
Color
White/Blue/Yellow for 20HP Air Compressor
Transport Package
Wooden Box or Pallet
Specification
Size: 1180*850*1150mm for 20hp COMPRESSOR
Trademark
Airstone, fengguang
Origin
Guangdong, China(Mainland)
HS Code
84148040
Production Capacity
5000pieces/Month

Product Description

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
Oil-flooded single-stage AC power 11kw 15hp vsd direct driven screw air compressor 

Capacity:1.5m3/min

Control: MAM880

Driven:Direct driven

Cooling: By Air

Protect level: IF23

Insulation level: F

Discharge temperature: less than ambient -5ºC+- 45ºC

Dimension: 1080*700*1000mm

Weight:310kg

Delivery time:20days

Warranty: 12 months

Configuration: mute and stationary  

Air End:Baosi airend

Compressor stage:Single-stage 

Voltage:220V/60HZ/3PH

Pressure:1.0Mpa

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor

airstone compressor motor: consign to professional motor manufacture to perform local processing with using powerful power output,extremely low operating temperature and energy conversion losses.Have anough temperature margin and stable operation,ensures long-term no-fault operation and reduce the motors faults.

We can provide fix speed motor,vsd motor,pm vsd motor

IP23/IP54/IP55

IE2/IE3

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
 

The air end  is connected with the motor through the flange and gear box.The axis is accurate in positioning,easy to install,low noise,less in failure,and safe in operation.

Shaft seal with PTFE material which has good lubricity and long working lifetime.

Triple oil seal and oil return structure reduce oil leakage

We can provide Baosi/Hanbell airend(AC/AB)

Single-stage/Double-stage

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
 

Efficient cooling fan 

Low rotating speed,low noise,large aur volume,high cooling efficience cooling fan by using large cooling system,never blocking,reducing compressor's exhaust temperature and extending working lifetime of the seals,bearings and luricating oil.

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
 

Oil separator tank

compared with similar products,the oil discharge is less than 2ppm-5ppm,which not only ensures the clarity of the air but also reduce the load of the air handling equipment.

The oil return hole connector can clearly see the oil return condition.

All piping uses an O-ring flat design,can completely eliminate leaks.

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
 

Air intake valve

Large diameter,low pressure differential reduced consumption.

Unique control design ro improve system stability;ensure the machine working.

 

for 40hp compressor 

Model number:AIV-85B-K 

Warranty:12 months

 

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor
 

Air/Oil filter,oil separator

High presicion can effectively filter the impurtiese in lubrication oil.
 

Warranty time 

Oil filter:2000H

Air filter:3000H

Oil separator:4000H

 

Oil-Flooded Single-Stage AC Power 11kw 15HP VSD Direct Driven Screw Air Compressor

The ControllerCan contrl the operation of parts accurately with collecting all operating data to diagnose and indicate the fault,Alert to protect the compressor ans ensure 24-Hpur unattended operation RS-485 communication function,support MODBUS RTU protocl reserved communication interface.For 40HP compressor


FAQ
Q1: Are you factory or trade company? 
A1:We are factory.
Q2: What the exactly address of your factory? 
A2: Our head office is located in 2F Xingshun Technology Park, Chongtou community,Chang'an, Dongguan City Guangdong Province,china.And our factory is located in Area B,Industry Zone,Lian hua County, Pingxiang City, Jiangxi Porvince, China. (That is our boss's hometown)
Q3: Warranty terms of your machine? 
A3: One year warranty for the machine and technical support according to your needs.
Q4: Will you provide some spare parts of the machines? 
A4: Yes, of course. we can provide all spare parts for the machines
Q5: How long will you take to arrange production? 
A5:380V 50HZ we can delivery the goods within 10 days. Other electricity or other color we will delivery within 14-18days
Q6: Can you accept OEM orders? 
A6: Yes, with professional design team, OEM orders are highly welcome.

Q7. Could I get some samples?
Yes, we can provide sample, but not free.

Q8. Could you Calculate the shipping cost for me?
Yes, we are honored to do that for you! Before the freight , please well let us know which seaport or airport near your place.
Q9. What's the delivery way?
Shipping way: air freight, express, sea
Q10. What's the payment?
We accept T/T, PAYPAL, RMB, MONEYGRAM, please advise which is better for you.

Q11.Reason of Air Compressor Difficult to Restart.
  1. The lubricating oil used is not the correct one. It should be thoroughly changed after cleaning;
  2. Oily sticky, coking, should be thoroughly changed after cleaning;
  3. The shaft seal is seriously leaking, and it is removed and replaced;
  4. The original position of the unloading flap changes and the position is re-adjusted.
Q12.The reason of abnormal temperature of screw air compressor.
1).The surrounding environment of the air compressor affects the heat dissipation of the air compressor. For example, the air compressor is too close to the wall or obstacles, there are other heat sources near the air compressor, and the front door or side door is open when the air compressor is running, resulting in a fan. The inability to form a strong air flow can result in poor ventilation and heat dissipation in the air compressor environment.
2) the radiator is blocked. When there is more dust in the surrounding environment of the air compressor, the long-term operation of the air compressor will cause a layer of dust or oil to adhere to the surface of the radiator, and the internal structure is also easily blocked due to the accumulation of grease, which affects the heat dissipation effect.
3).the oil filter is too dirty. When the oil filter in the compressor is too dirty, the resistance oil cannot enter the compressor at the normal flow rate, and the compressor will heat up rapidly due to insufficient cooling oil. When the oil pressure difference between the inlet and outlet exceeds 0.18Mpa, the filter element needs to be replaced.
4). The cooling oil level is too low. When the air compressor is inspected by the cold machine, the oil level should be replenished immediately below the lower end of the inspection tube.
5), low oil label or poor oil quality. The air compressor adopts the special compressor oil of the manufacturer. When other low-grade or inferior oil is used, the viscosity and specific heat will not reach the standard, resulting in excessive temperature.
6). The fan tape is broken or slack. When the tape is broken, the air compressor will run automatically for about 5 minutes, because the temperature is too high, it will stop automatically. If the tape is too loose, it will slip, which will reduce the fan speed and affect the heat dissipation. Therefore, it is necessary to replace or adjust the tightness of the fan tape.
7), the oil shut-off valve is out of order. There is a fuel cut-off valve between the oil filter and the compressor. When the oil shut-off valve cannot be opened, there is no lubricating oil and cooling. After the compressor starts, the temperature rises rapidly, and about 1Min will stop automatically. The temperature plug of the exhaust end of the compressor main unit should be removed, and it is found that the temperature plug is dry and oil-free, and there will be blue smoke floating out of the hole. Open the air compressor access hole, remove the oil shut-off valve, and gently push the valve stem with your fingers to see if it can be pushed back and forth or can be easily reset. If it is difficult to move or return, it is necessary to further reduce the disintegration of the oil valve. If the valve stem or valve hole is greased, it needs to be sanded with fine sandpaper until it can slide easily. If the spring is broken or there is a foreign matter card, it will affect the movement of the valve stem. In this case, you need to replace the spring or the cleaning spring or the spring seat.
8), the oil separator core is too dirty. When the oil separator core is too dirty, the oil will affect the circulation due to excessive resistance, causing overheating shutdown. If this happens, the pressure difference between before and after loading should be judged. When the pressure difference between the two ends is the initial or maximum pressure difference of 0.1Mpa at the beginning of the startup, the oil separator core should be cleaned or replaced.
9). The thermostat bypass valve is in the open position. The thermostat bypass valve is in the open position when the machine is cold, and gradually closes after the temperature rises. When it fails, it may remain in the open position, and the cooling oil will flow back directly from the air compressor without passing through the radiator, so the temperature will rise slowly and cause the machine to stop. The inspection method is similar to the oil valve inspection method.
10), the exhaust pressure is too high. When the exhaust pressure exceeds the rated pressure, the long-term operation will cause the air compressor to stop due to the excessive load of the compressor and the diesel engine. If this happens, check and adjust the pressure valve first, then check the diesel throttle control system and eliminate the fault.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now