No. | Parameter | Value |
1 | Quantity, pcs | 1 |
2 | Application | Compressed air production |
Unit parameters | ||
3 | Unit capacity, nm3/min (0°C, 101.3 kPa) | 45 |
4 | Unit capacity, m3/min (20°C, 101.3 kPa) at standard conditions | 50 |
5 | Arrangement type | Block box |
6 | Nominal max pressure of the unit, MPa | 0,8 (0,9) |
7 |
Compressed air consumers | - Stands for pneumatic tests; - Blasting chamber; - Paint-drying chamber; - Pneumatic tools; - Metalworking machines. |
8 | Compressor station design | Permanent Magnet Variable speed |
9 | Number of operating hours per year, (h/year) | 8760 |
10 |
Operating mode | Air consumption is not constant, possible spikes in air consumption. |
11 | Preheater | no |
12 | Сompressor redundancy | Yes (100%) |
13 | Required air purity class acc. to ISO 8573-1-2005 | 3.2.3 |
14 | Required dew point, °С | Max minus -40 (pressurized) |
Compressor parameters | ||
15 | Quantity, pcs. | 2 |
16 | Compressor type | Oil-lubricated screw compressor |
17 | Compressor cooling system | Air |
18 | Compressor capacity control method | Yes (Automatic) |
19 | Temperature of compressed air leaving the compressor, °С | ≤+40 |
20 | Compressor power, kW | 132 |
21 | Supply voltage, V | 380 |
22 | Current frequency, Hz | 50 |
23 | IP | min IP 54 |
24 | Type of compressor assembly | inside the complete block box |
Block box installation conditions | ||
25 | Climate of the construction area: note 2) | |
26 | - abs min air temperature, °С | minus 47 |
27 | - abs max air temperature, °С | plus 40 |
28 | air temperature of the coldest five-day period, °С, with probability of 0.92 | minus 31 |
29 | air temperature of the coldest day, °С, with probability of 0.92 | minus 35 |
30 | - air temperature of the coldest day, °С, with probability 0.98 | minus 38 |
31 | - air temperature of the warmest days, °С, with probability of 0.98 | +27 |
32 | - humidity zone | normal |
33 | average relative humidity of the air of the coldest month of the year, % | 82 |
34 | - average relative air humidity of the warmest month of the year, % | 67 |
35 | - prevailing wind direction | southwest |
36 | - standard value of wind pressure, kPa (kgf/m2) | 0.30 kPa (30 kgf/m2) (II wind region) |
37 | - standard value of snow pressure, kPa (kgf/m2) | 2.1 kPa (210 kgf/m2) |
38 | - seismicity of the construction site, points | Up to 7 |
39 | Place of installation | Outside |
40 |
Placement category | For outdoor operation, operating temperature range: 45...+40 °С . |
41 | Guaranteed service life of the equipment, (years) | 20 |
42 | Number of operating hours per year, (h/year) | 8040 |
43 | Time between overhauls of the equipment, (years/year) | 2 |
56 | Porch with a shelter in front of the entrance door, (yes/no) | Yes |
57 | Windows: | |
58 |
Number of windows, pcs. | to be determined by the supplier taking into account the standards |
59 | Size of windows, (width/height), mm | 900/1100 |
60 | Protective external grids, (yes/no) | Yes |
61 | Protective mosquito nets, (yes/no) | no |
62 | Electrical wiring, (open/in cable channels/other) | in cable ducts |
63 | Internal lighting, (yes/no) | yes |
64 | Number of lamps, pcs: | See note 10 |
65 | Type of lamps | LED |
66 | Emergency lighting: | Yes, backup and escape route lighting |
67 | Number of outlets, pcs: | 2 pcs, IP55 with protective shutters |
68 | Max installed power (kW): | Compressor+Freezer air dryer+adsorption air dryer |
69 |
Street lighting, (yes/no) | Yes, in front of the entrance, above the door, controlled by light relay |
70 | Heating, (yes/no) | Yes |
71 | Ventilation: | Infrared heater or electric convector |
72 | Climate requirements inside the box: | To be determined by the supplier |
73 | Air temperature in the room in the cold season, °С | min + 5 (To be specified by the manufacturer) |
74 | Air temperature in the room in warm period of the year, °С | max + 35 (To be specified by the manufacturer) |
75 | Fire alarm system, (yes/no) | yes |
76 | Utilities, (yes/no) | yes |
77 | Insulation in the box design, (yes/no) | Yes (walls, roof, floor), NG- type. |
78 | Building fire resistance degree | II |
79 | Grounding circuit, (yes/no). | yes |
80 | Lightning protection, (yes/no). | yes |
81 | Auxiliary power supply panel | yes |
82 | Technological video surveillance | yes |
Scope of supply | ||
83 | Compressor unit (yes/no), set. | Yes, 1 set. |
84 |
Compressor (yes/no), pcs. | Yes, 2 pcs. Capacity of each compressor 100% |
85 | Compressor incl.: | |
86 | Noise-absorbing casing, (yes/no) | yes |
87 | Axial cooling fan, (yes/no) | yes |
88 | Air flow pre-filter, (yes/no) | yes |
89 | Air end aftercooler, (yes/no) | yes |
90 | Frequency converter, (yes/no) | yes |
91 | Pre-drier filter, (yes/no), pcs. | yes |
92 | Dehumidifier with dew point max minus 40 (pressurized), (yes/no). | yes |
93 | Filter downstream of dehumidifier, (yes/no) | yes |
94 |
Electronic control unit of the compressor unit with controller- regulator for simultaneous control of two compressors, each with variable frequency drive | yes |
95 | Emergency stop button for compressor unit (yes/no) | yes |
96 | Sensors and instrumentation devices (yes/no) | yes |
97 | Condensate treatment unit | yes |
98 | Receiver | To be specified by the manufacturer |
99 | Piping (fittings, pipes, fasteners, supports), (yes/no) | yes |
100 | Connection nozzles (yes/no) | yes |
101 | Equipment grounding | yes |
102 | Load-carrying devices for mounting (lugs, etc.) | yes |